Pressure Reducer Adjustable Pressure

 

Features

R14, R16

Non-relieving models for air and water service

Relieving models for air service allow reduction of

outlet pressure even when the system is dead-ended

R14 has aluminum body and bonnet

R16 has brass body and bonnet

Factory preset, tamper resistant pressure setting

Non-repairable

Miniature, Preset, Nonadjustable Pressure Regulator

Water and Compressed Air Service

1/8" or 1/4" PTF Port Sizes

Alternative Models R   -    -    

Port Size Substitute

1/8" 1

1/4" 2

Threads Substitute

PTF A

** The 8th and 9th positions of the model number contain the Modified Outlet Pressure Setting. The Modified Outlet Pressure Setting is the desired outlet pressure,

modified to allow for inlet pressures other than 100 psig, and for flows other than zero. Insert the modified outlet pressure setting in positions 8 and 9 as described below.

1. Write down the desired outlet pressure and the flow through the regulator. EXAMPLE: 30 psig outlet pressure at 10 scfm flow.

2. Modifications for inlet pressures other than 100 psig:

If inlet pressure exceeds 100 psig*, add 1 psig to the desired outlet pressure for each 20 psig the inlet pressure is above 100 psig*.

EXAMPLE: If the inlet pressure is 180 psig, add 4 to the desired outlet pressure. Following through with the example in step 1, add 4 to 30 for a modified outlet pressure setting of

34 psig.

If inlet pressure is less than 100 psig*, subtract 1 psig from the desired outlet pressure for each 20 psig the inlet pressure is below 100 psig*.

EXAMPLE: If the inlet pressure is 60 psig, subtract 2 from the desired outlet pressure. Following through with the example in step 1, subtract 2 from 30 for a modified outlet

pressure setting of 28 psig.

3. Modifications for flows other than zero:

Determine the pressure drop from the appropriate flow curve above. Add the pressure drop to the modified outlet pressure setting.

EXAMPLE: If the desired outlet pressure is 30 psig at a flow of 10 scfm, add 10 to the modified outlet pressure setting. The quantity of 10 is the difference between the outlet

pressure (30 psig) at the desired flow (10 scfm) and outlet pressure (40 psig) at no flow. See dashed lines on the air flow curve for example. Following through with the first

example in Step 2 above, add 10 to the 34 to obtain a modified outlet pressure setting of 44. Enter 44 in the 8th and 9th positions of the model number.

* 125 psig for outlet pressure settings of 95 through 99 psig.

Diaphragm Substitute

Relieving R

Non relieving N

Gauge ports in body Substitute

With gauge ports 00

Without gauge ports 01

Ordering Information. Models listed are relieving type for compressed air service with PTF threads and with gauge ports

Port Model Flow scfm (dm3/s) Flow U.S. gpm (lpm) Weight lb (kg)

1/8" PTF R14-100-R**A 12 (5.7) 1.3 (4.9) 0.2 (0.09)

1/8" PTF R16-100-R**A 12 (5.7) 1.3 (4.9) 0.7 (0.32)

1/4" PTF R14-200-R**A 12 (5.7) 1.3 (4.9) 0.2 (0.09)

1/4" PTF R16-200-R**A 12 (5.7) 1.3 (4.9) 0.7 (0.32)

Approximate flow with 100 psig (7 bar) inlet pressure, 80 psig 5.5 bar() set pressure and a 15 psig (1 bar) droop from set.

Approximate flow with 100 psig (7 bar) inlet pressure, 60 psig (4 bar) set pressure and a 15 psig (1 bar) droop from set.

Type/Service Substitute

Piston; air service only 14

Diaphragm; air and water service 16

See Section ALE-24 for Accessories

R14 and R16 Special Purpose Regulators

ALE-5-9

All Dimensions in Inches (mm)

Littleton, CO USA Phone 303-794-2611 www.norgren.com

Technical Data

Fluid

R14: Compressed air

R16:Water and compressed air

Maximum pressure: 400 psig (27 bar)

Operating temperature

Water service: 35 to 175F (2 to 79C)

Air service: -30 to 175F (-34 to 79C) *

* Air supply must be dry enough to avoid ice formation at temperatures below 35F (2C).

Type

R14: Piston, relieving or non-relieving

R16: Diaphragm. relieving or non-relieving

Typical flow for water service at 100 psig (7 bar) inlet pressure, 60 psig (4 bar) set

pressure and a droop of 15 psig (1 bar) from set: 1.3 U.S. gpm (4.9 liters per

minute)

Typical flow for compressed air service at 100 psig (7 bar) inlet pressure, 80 psig

(5.5 bar) set pressure and a droop of 15 psig (1 bar) from set: 12 scfm (5.7

dm3/s)

Gauge ports: 1/8" PTF

Factory preset outlet pressure settings: 0,2 to 6,8 bar (3 to 99 psig)

Outlet pressure tolerance:

Outlet pressure setting - psig (bar) Tolerance - psig (bar) **

3 to 20 psig (0.21 to 1.38 bar) 1.0 psig (0.07 bar)

21 to 50 psig (1.45 to 3.45 bar) 2.0 psig (0.14 bar)

51 to 99 psig (3.52 to 6.84 bar) 3.0 psig (0.21 bar)

** When outlet pressure is preset at the factory, the following conditions exist

Flow thru regulator: No flow

Inlet pressure:

100 psig (6.9 bar) for outlet pressures up through 95 psig (6.6 bar)

125 psig (8.6 bar) for outlet pressures of 96 through 99 psig

(6.7 through 6.8 bar)

Materials

Body and bonnet

R14: Aluminum

R16: Brass

Valve: Brass

Valve seat: Acetal resin

Elastomers: Nitrile

ISO Symbols

Relieving Non relieving

PORT SIZE 1/8", 1/4"

INLET PRESSURE: 100 psig (7 bar)

WATER FLOW CHARACTERISTICS

0 2 4 6 8 10 litres/min

WATER FLOW

0 0.5 1.0 1.5 2.0 2.5 US gal./min

OUTLET PRESSURE

8

6

4

2

0

bar

100

80

60

40

20

0

psig

PORT SIZE: 1/8", 1/4"

INLET PRESSURE: 100 psig (7 bar)

AIR FLOW CHARACTERISTICS

0 2 4 6 8 10 dm3/s

AIR FLOW

OUTLET PRESSURE

8

6

4

2

0

bar

10 psig Difference

100

80

60

40

20

0

psig

30

0 4 8 10 12 16 20 scfm

Typical Performance Characteristics

R14

2.58 (65)

0.40 (10)

1.48 (38)

1.48 (38)

2.28 (58)

0.40 (10)

1.48 (38)

1.48 (38)

R16

R16 brass bonnet & body combination max temperature 200F